How to Create an Evacuation Plan at Work
- Posted by Sam Yates
- On November 13, 2026
- 0 Comments
A fire alarm is only useful if people know what to do when it sounds. In an occupied office, block of flats, school, place of worship or warehouse, uncertainty can turn a manageable evacuation into a dangerous delay. Knowing how to create an evacuation plan means setting out practical arrangements that suit the building, its occupants and the risks identified in your fire risk assessment.
For most non-domestic premises in England and Wales, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to establish and, where necessary, give effect to appropriate procedures for serious and imminent danger. An evacuation plan is a central part of that duty. It should not be a generic drawing displayed by the fire exit. It must work during a real incident, including when the usual manager is absent, visibility is poor or visitors are unfamiliar with the building.
Start with the building and its fire risk assessment
An evacuation plan should follow the findings of a suitable and sufficient fire risk assessment, rather than be written in isolation. The assessment identifies the people at risk, possible sources of fire, escape routes, fire doors, alarm arrangements, emergency lighting and measures needed to reduce risk. Those details determine whether immediate evacuation is appropriate and how it can be achieved safely.
Begin by confirming how the premises are used throughout the day and outside normal hours. A small office occupied only during weekday hours has different needs from an HMO, care setting, community hall or mixed-use building with contractors and members of the public. Consider lone workers, sleeping occupants, shift patterns, people working in isolated areas, deliveries and events that increase visitor numbers.
Your plan must also reflect the building layout. Identify every final exit, protected stairway, corridor, refuge point and assembly point. Check that escape routes lead to a place of ultimate safety, not simply into another part of the building. A route that appears adequate on a floor plan may be unsuitable in practice if it is often obstructed by stock, parked equipment, furniture or refuse bins.
Decide the evacuation strategy
The most suitable strategy depends on the premises and should be supported by the fire risk assessment. In many workplaces, shops and public buildings, a simultaneous evacuation is appropriate: on hearing the alarm, everybody leaves immediately by the nearest safe exit.
Other buildings may need a phased or zoned evacuation. This is more common in larger, complex premises where an alarm activates in stages to prevent stairs and exits becoming overloaded. Residential buildings may use a stay-put policy, particularly where flats are designed as separate fire-resisting compartments. That arrangement must never be copied casually from another property. Changes to compartmentation, cladding, fire doors, occupancy or the needs of residents can affect whether it remains suitable.
The evacuation strategy should state plainly what occupants are expected to do. Avoid ambiguous instructions such as “leave if safe”. People need a clear trigger, normally the fire alarm, and a clear instruction to leave by the nearest available escape route, without returning for belongings.
Define routes, exits and assembly arrangements
A good evacuation plan makes the first few minutes predictable. Mark primary escape routes and realistic alternatives on clear plans, using symbols people can understand quickly. The plan should show fire alarm call points, fire extinguishers where relevant, exits, stairways and the external assembly point.
Do not assume the main entrance is always the safest exit. A fire or smoke condition could make it unusable. Staff should understand that they may need to use an alternative route, but should not be asked to pass through smoke or open a door that feels hot. They should leave the building and report the issue once outside.
Choose an assembly point far enough from the premises to avoid smoke, falling debris and obstruction to emergency vehicles. It should not require people to cross a vehicle route unnecessarily. For multi-occupied sites, separate assembly points can make roll calls more manageable, provided they are clearly communicated and do not create confusion.
Keep escape routes under routine control. Fire doors should close effectively and must not be wedged open. Final exits must be readily available when the premises are occupied. Storage, displays and equipment must not reduce the usable width of corridors or stairways. These operational details are often where otherwise sound plans fail.
Allocate people and responsibilities
An evacuation plan needs named roles, deputies and straightforward instructions. Relying on a single fire marshal is risky if that person is on leave, working remotely or has already left the area.
Depending on the size and nature of the premises, responsibilities may include:
- raising the alarm and calling the fire and rescue service where required;
- checking designated areas only when it is safe to do so;
- directing occupants towards safe exits and preventing re-entry;
- taking visitor, staff or resident records to the assembly point; and
- reporting missing persons, relevant hazards and the location of any fire to attending firefighters.
Fire wardens should not be expected to search through smoke, tackle a fire or delay their own escape. Their role is to support an orderly evacuation within the limits of their training and personal safety. Make this boundary explicit.
For visitor-facing premises, reception procedures matter. Visitors should be signed in, given concise evacuation information and accompanied where necessary. Contractors require particular attention because they may be working in plant rooms, roof spaces, service risers or other areas away from normal circulation routes.
Plan for people who may need assistance
A plan that only works for independently mobile occupants is incomplete. Consider anyone who may need help because of mobility, sight, hearing, neurodiversity, temporary injury, pregnancy, language barriers or unfamiliarity with the building.
A Personal Emergency Evacuation Plan, commonly called a PEEP, sets out agreed arrangements for an individual who needs assistance. It should be developed sensitively with the person concerned and reviewed when their circumstances or workplace change. The plan may cover assistance from a colleague, evacuation chairs, accessible alarm notification, refuges and communication arrangements.
A refuge is not an end point. Where used, it needs suitable fire resistance, two-way communication and a managed procedure for alerting those responsible to the person’s location. Never assume that emergency services will automatically know someone is waiting there.
For occasional visitors, a General Emergency Evacuation Plan may be more appropriate. The key is that staff know how to identify a need for support and respond without creating unsafe lifting or carrying arrangements. Specialist advice and appropriate equipment may be required.
Write clear instructions and train people to use them
The written plan should be concise enough to use under pressure, while retaining the supporting detail needed for management. It should state the alarm signal, evacuation strategy, escape routes, assembly point, responsible roles, roll-call process, arrangements for people requiring assistance and the procedure for liaising with the fire and rescue service.
Display simple evacuation notices at relevant points, but do not treat signage as training. Induct new employees, regular volunteers and long-term contractors. Explain the alarm sound, the nearest exits, the assembly point and the rule against re-entering until an authorised person confirms it is safe.
Training should be proportionate. A low-risk, single-storey office may need clear induction and periodic refresher training. A school, healthcare environment or complex site with multiple shifts will generally need more structured instruction, scenario-based exercises and careful handover between teams.
Test the plan through drills and review the evidence
A fire drill is a practical test, not a box-ticking exercise. It reveals whether alarm audibility is adequate, exits are available, wardens understand their roles and roll-call information is accurate. Observe the drill, record the outcome and assign actions with owners and timescales.
Useful observations include whether people hesitated, used lifts, returned for possessions, gathered in the wrong place or found a route blocked. Repeated late evacuation from a particular area may indicate inadequate alarm coverage, poor staff briefing or a layout issue that needs investigation.
Review the evacuation plan after a drill, fire incident, false alarm, significant change to the building, change in occupancy or findings from the fire risk assessment. Keep current plans, training records, drill records and corrective actions accessible. Digital document control is particularly useful where managers, managing agents and duty holders need to demonstrate that arrangements are current.
When professional input is needed
Some evacuation arrangements require more than a template. Seek competent fire-safety advice where there are sleeping risks, high-rise or complex premises, vulnerable occupants, phased evacuation, significant alterations, recurring alarm problems or uncertainty over whether the existing strategy remains appropriate.
A thorough fire risk assessment can connect the physical condition of the building with the practical realities of evacuation, producing clear actions rather than vague recommendations. Firelux supports property stakeholders across London and the South East with documented, insurance-compliant assessments and practical follow-up advice where evacuation arrangements need attention.
The strongest evacuation plan is the one people can follow without hesitation. Keep it specific to the premises, make responsibilities realistic, and test it before an emergency decides whether it works.

0 Comments